DBO-432-AC-HTP100EX
Certified LED helideck Circle and H identification system control panel
Certified LED helideck touchdown/positioning and heliport identification marking system control panel designed to meet the requirements of CAP437, when used in conjunction with the separate touchdown/positioning (Circle) and helideck identification marking (H) lighting panels.



Key features
- Suitable for Zone 1 areas with increased gas explosion hazard
- Suitable for control of the helideck touchdown/positioning marking panels and heliport identification marking panels
- Skid or direct wall mounting of control panel possible
- Offshore resistant, high quality coating on the sheet steel enclosure
- Sheet steel mounting facilities to prevent corrosion problems
Electrical characteristics
- Operating voltage: Multi-voltage AC input available (110-254 Vac)
- System power consumption:
max. 160 W including panels load - Connection details:
M25x1.5 cable gland entries
Standards/Certification
- Complies with CAA-UK CAP 437; 9th edition appendix C
- KEMA 02ATEX2103 X;
ATEX Ex II 2G Ex d e IIB T5, according to ATEX Directive 94/9/EC - EN 60079-0, EN 60079-1,
EN 60079-7, EN61241-0 and
EN61241-1 - IECEx KEM 09.0089X;
Ex d e IIB T5 - IEC 60079-0, IEC 60079-1,
IEC 60079-7, IEC 61241-0 and
IEC 61241
Physical characteristics
- Dimensions (L x W x H):
341.5x 360 x 865 mm - Weight: 85 kg
- Degree of protection: IP66
- Operating temperature range: -40°C to +55°C
System design, control and monitoring
- System Power – ON, Auto/Remote
- Power on indication
- System fail contact