FH800EX-1
Explosion proof foghorn
Explosion proof foghorn, designed to provide 0.5 nautical miles omni-directional coverage. For man-made offshore structures and in line with IALA regulatory requirements. Can be supplied as a main/secondary (2+½ Nm) foghorn together with duplicated controls in the Navaid Central Control Panel (NCCP).
Key features
- Reliable marine foghorn, low cost of ownership
- Suitable for Zone 1 and Zone 2 areas with gas explosion hazard; ATEX & IECEx certified
- Operating voltage and code control provided from Navaid Central Control Panel (NCCP)
- Monitoring system integrated in Navaid Central Control Panel (NCCP)
- Offshore coated seawater resistant light alloy body
System design, control and monitoring
- Control and monitoring via separate control panel (see separate Custom engineering sheet)
Performance characteristics
- Morse code ‘U’ every 30 seconds from Navaid Central Control Panel (NCCP)
- Usual range main foghorn: 0.5 NM
- Horizontal sound output: 360°
Standards/Certification
- Complies with UK Department of Energy and Climate Change; Standard marking schedule for offshore installations – April 2011; chapter 4 – secondary fog signal
- Cenelec EN 60079-0, EN 60079-1 and EN 60079-7
- KEMA 02ATEX2269 (foghorn); ATEX II 2G Ex eb llC T6 Gb
- KEMA 02ATEX2103 X (junction box); ATEX II 2G Ex db llB T6 Gb
- IEC 60079-0, IEC 60079-1 and IEC 60079-7
- IECEx DEK 11.0105 (foghorn); Ex eb IIC T6 Gb;
- IECEx KEM 09.0089X (junction box); Ex db IIB T6 Gb
- ABNT NBR IEC 60079-0, ABNT NBR IEC 60079-1 and ABNT NBR IEC 60079-7 (optional)
- Inmetro NCC 13.1778 (foghorn) (optional)
- Inmetro NCC 22.0085 X (junction box) (optional)
Electrical characteristics
- Operating voltage: 190 Vac; 860 Hz from Navaid Central Control Panel (NCCP)
- Power consumption: 25 W peak max (Digital modular NCCP)
- Connection details: max. 4 mm²; one M25x1.5 cable gland entry
- Earth connection: internal 4 mm²and external M6
Physical characteristics
- Dimensions (L x W x H):
678 x 464 x 694mm - Weight: 70 kg; lifting eye suitable for lifting 700 kg
- Degree of protection: IP66
- Operating temperature range:
–55°C to +55°C