Explosion proof LED helideck floodlight to provide illumination of the landing area of the helideck.

Orga Offshore – Datasheet Drawing – HFL100EX-XX-XX-x – – r04-03-01
Orga Offshore – Datasheet Drawing – HFL100EX-XX-XX-x – – r04-03-02
Orga Offshore – Datasheet Drawing – HFL100EX-XX-XX-x – – r04-03-03

Key features

  • Reliable LED floodlight gives low cost of ownership and maintenance
  • Low power consumption due to highly efficient LED light source and lens system
  • Certified for Zone 1 areas with gas explosion hazard
  • Low profile design (<250 mm) allows direct mounting on helideck
  • Offshore resistant, high quality coating on cast light alloy base
  • Stainless steel mounting facilities to prevent corrosion problems, and integrated junction box
  • Wide beam spread for optimum equal helideck illumination
  • Easy aiming facility to meet requirement of computer simulation for helideck illumination

Performance characteristics

  • Highly efficient LED light source and lens system
  • No glare
  • Aiming facilities provided

Standards/Certification

  • Complies with ICAO Annex 14, Volume ll; International standards and recommended practices: Aerodromes, July 2013, chapter 5, paragraph 5.3.9 – Helideck Floodlights
  • Complies with Normam 27; Chapter 5; Section 0505d
  • Complies with Norsok C-004; Section 18.3
  • KIWA 17ATEX0005 X; ATEX II 2 G Ex db eb op is IIB T4 Gb
  • EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-28
  • IECEx KIWA 17.0003X; Ex db eb op is IIB T4 Gb
  • IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 60079-28
  • ABNT NBR IEC 60079-0, ABNT NBR IEC 60079-1, ABNT NBR IEC 60079-7 and ABNT NBR IEC 60079-28 (optional)
  • Inmetro NCC 18.0033X (optional)

Electrical characteristics

  • Operating voltage: see table
  • Power consumption: See table
  • Connection details: max. 4 mm²; 2 x M25x1,5 cable gland entries
  • Earth connection: internal max. 4 mm² and external M5

Physical characteristics

  • Dimensions (L x W x H):
    250 x 480 x 215 mm
  • Weight: max 20Kg
  • Degree of protection: IP66
  • Operating temperature range:
    -50°C to +55°C

System design, control and monitoring

  • When used in a floodlight system the average horizontal illuminance of the floodlighting will meet the regulatory requirements of at least 10 lux, with a uniformity ratio (average to minimum) of not more than 8:1 measured on the surface of the TLOF.