CAP 437 explosion proof LED heliport identification marking light panel used in conjunction with a control panel and the Heliport Identification Marking (‘H’). Long life LEDs and light weight design, which is suitable for direct mounting on the helideck due to the low profile (<25mm), makes the product ideal for the environmental conditions as well as easy installation.

htp100ex-g-technical-drawing-1
htp100ex-g-technical-drawing-2
htp100ex-g-technical-drawing-3

Key features

  • Panel used for heliport identification marking system; ‘H’
  • Suitable for Zone 1 and 2 areas with gas explosion hazard
  • Low profile design (<25mm) allows direct mounting on helideck
  • Offshore resistant, fully sealed, high quality marine plastic materials
  • Semi-flex construction to allow for deck distortions and improved impact resistance
  • Stainless steel (SS316) mounting brackets to prevent corrosion problems, and integrated cable connection
  • State of the art high power LEDs and technology provide superior life and reliability
  • Fully offshore trialled to meet the operational and environmental requirements

Physical characteristics

  • Dimensions (L x W x H):
    503 x 290 x 24mm
  • Weight: 0.8kg
  • Degree of protection: IP66, IP67 and IP69
  • Operating temperature range:
    -25°C to +55°C

Standards/Certification

  • Certified to CAA-UK CAP 437; 9th edition appendix C
  • ABS Certificate Product Design Assessment- Orga CAP437 TD/PM Circle-H System – 20-2004182-PDA
  • EN 60079-0, EN 60079-7, EN 60079-11 and EN 60079-18
  • DEKRA 11ATEX0186; ATEX II 2 G Ex e mb [ib] IIC T6 Gb
  • IEC 60079-0, IEC 60079-7, IEC 60079-11 and IEC 60079-18
  • IECEx DEK 11.0072; Ex e mb [ib] IIC T6 Gb
  • ABNT NBR IEC 60079-0, ABNT NBR IEC 60079-7, ABNT NBR IEC 60079-11, ABNT NBR IEC 60079-18
  • NCC 23.0080; Ex eb mb [ib] IIC T6 Gb (optional)

Performance characteristics

  • Steady burning; Green
  • Effective intensity: 2-12° max. 60cd; 12-20° max. 30cd and 20-90° max. 10cd
  • Horizontal beam coverage: 360°
  • Vertical beam profile: in compliance with above mentioned CAA requirements
  • Colour chromaticity within the boundaries as specified by CAA

Electrical characteristics

  • Operating voltage: Low (10-17V) DC input from Orga control panel
  • Power consumption: 0.2W average
  • Connection details: Orga custom offshore

System design, control and monitoring

  • Fault monitoring with fail indication via separate system control and monitoring box (see separate data sheet)
  • Custom designed cables with vulcanized cable termination protection and captive connection screws; multiple lengths to allow for all configurations